Honeywell T8602D Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Termostaty Honeywell T8602D. Honeywell T8602D User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
® U.S. Registered Trademark
Copyright © 2003 Honeywell International Inc. • • All Rights Reserved
INSTALLATION INSTRUCTIONS
69-1510-
4
T8602D Chronotherm® IV
Programmable Thermostats
APPLICATION
The T8602 Chronotherm® IV Programmable Thermostat
provides electronic control of 24 Vac single-stage heating
and cooling systems or 750 mV heating and 750 mV
cooling. Refer to Table 1 for a general description of the
thermostat. All T8602 Thermostats are powered by
batteries.
MERCURY NOTICE
If this control is replacing a control that contains
mercury in a sealed tube, do not place your old
control in the trash. Dispose of properly.
Contact your local waste management authority
for instructions regarding recycling and the
proper disposal of the old control.
INSTALLATION
When Installing this Product...
1. Read these instructions carefully. Failure to follow
the instructions can damage the product or cause
a hazardous condition.
2. Check the ratings given in the instructions and on
the product to make sure the product is suitable for
your application.
3. Installer must be a trained, experienced service
technician.
4. After completing installation, use these instructions
to check out the product operation.
Location
Install the thermostat about 1.5m (5 ft) above the floor in
an area with good air circulation at average temperature.
See Fig. 1.
Do not install the thermostat where it can be affected by:
drafts, or dead spots behind doors and in corners.
hot or cold air from ducts.
radiant heat from sun or appliances.
concealed pipes and chimneys.
unheated (uncooled) areas such as an outside wall
behind the thermostat.
Wallplate Installation
The thermostat can be mounted horizontally on the wall
or on a 50.8 mm x 101.6 mm (2 in. x 4 in.) wiring box.
Position wallplate horizontally on the wall or on a
50.8 mm x 101.6 mm (2 in. x 4 in.) wiring box.
1. Position and level the wallplate (for appearance
only). The thermostat will function properly even
when not level.
2. Use a pencil to mark the mounting holes. See Fig.
2.
3. Remove the wallplate from the wall and drill two
4.76 mm (3/16 in.) holes in the wall (if drywall) as
marked. For firmer material such as plaster, drill
two 5.56 mm (7/32 in.) holes. Gently tap anchors
(provided) into the drilled holes until flush with the
wall.
4. Position the wallplate over the holes, pulling wires
through the wiring opening.
5. Loosely insert the mounting screws into the holes.
6. Tighten mounting screws.
Table 1. Description of T8602 Thermostats.
T8602 System Changeover
System
Selection
Fan
Selection Comments
D Heat-Cool Manual or
Automatic
Selectable
Heat-Off-Cool or
Heat-Off-Cool-Auto
On-Auto System and fan selections are done
by keyboard.
Przeglądanie stron 0
1 2 3 4 5 6 ... 11 12

Podsumowanie treści

Strona 1 - Programmable Thermostats

® U.S. Registered TrademarkCopyright © 2003 Honeywell International Inc. • • All Rights Reserved INSTALLATION INSTRUCTIONS69-1510-4T8602D Chronot

Strona 2 - 69-1510-4 2

T8602D CHRONOTHERM® IV PROGRAMMABLE THERMOSTATS69-1510-4 10THERMOSTAT INFORMATION1. Press the Time ∆ key to access the thermostat information.2. Press

Strona 3 - Mounting Thermostat

T8602D CHRONOTHERM® IV PROGRAMMABLE THERMOSTATS11 69-1510-4TROUBLESHOOTING GUIDETable 6. Troubleshooting Guide.Symptom Possible Cause ActionDisplay wi

Strona 4 - SETTINGS

69-1510-4 G.H. Rev. 03-03 www.honeywell.com/yourhomePrinted in U.S.A. on recycled paper containing at least 10% post-consumer paper fibers.Autom

Strona 5 - INSTALLER SETUP

T8602D CHRONOTHERM® IV PROGRAMMABLE THERMOSTATS69-1510-4 2Fig. 1. Typical location of thermostat.Fig. 2. Mounting the wallplate.WIRINGAll wiring must

Strona 6 - 69-1510-4 6

T8602D CHRONOTHERM® IV PROGRAMMABLE THERMOSTATS3 69-1510-4Fig. 4. Typical hookup in heat and cool system with one transformer.Fig. 5. Typical hookup i

Strona 7 - 7 69-1510-4

T8602D CHRONOTHERM® IV PROGRAMMABLE THERMOSTATS69-1510-4 4Using Thermostat KeysThe thermostat keys are used to:• set current day and time,• program ti

Strona 8 - INSTALLER SYSTEM TEST

T8602D CHRONOTHERM® IV PROGRAMMABLE THERMOSTATS5 69-1510-4Temperature SettingsRefer to Table 2 for the default program settings. If the daytime energy

Strona 9 - 9 69-1510-4

T8602D CHRONOTHERM® IV PROGRAMMABLE THERMOSTATS69-1510-4 6Table 3. Thermostat Installer Setup Options.SelectInstaller Setup Number (Press Time ∆ key t

Strona 10 - CHECKOUT

T8602D CHRONOTHERM® IV PROGRAMMABLE THERMOSTATS7 69-1510-4IMPORTA N TReview the settings to confirm that they match the system. Press Run Program to e

Strona 11 - TROUBLESHOOTING GUIDE

T8602D CHRONOTHERM® IV PROGRAMMABLE THERMOSTATS69-1510-4 8Setting Current Day and Time1. Press Set Current Day/Time.NOTE: On initial powerup or after

Strona 12 - Printed in U.S.A. on recycled

T8602D CHRONOTHERM® IV PROGRAMMABLE THERMOSTATS9 69-1510-4NOTE: Press any key and the displayed numbers will change. Press Time ∇ to go to the previou

Komentarze do niniejszej Instrukcji

Brak uwag