Honeywell Scanner MS9520 Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Czytniki kodów kreskowych Honeywell Scanner MS9520. Honeywell Scanner MS9520 User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 116
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów

Podsumowanie treści

Strona 1 - MetroSelect

MetroSelect® Single-Line Scanner Configuration Guide

Strona 2 - Trademarks

2–2 Code 128 ³ 1 0 0 1 1 3 * Enable Code 128 ³ 1 0 0 1 0 3 Disable Code 128 ³ 1 0 0 3 1 4 Enable UCC/EAN-128 ‘]C1’ Code Formatting – For Coupo

Strona 4 - Code Formatting

21–1 IS4125 and IS4225 Scan Engines ³ 1 2 0 3 1 5 Disable Old Serial Program ³ 1 2 0 3 0 5 Enable Old Serial Program ³ 1 2 0 3 1 1 Enable TTL U

Strona 5

21–2

Strona 6

22–1 IS4823 and IS4825 Scan Engines Operating Modes Activation Modes ³ 4 1 8 3 0 4 * Activate Scanning with the External Trigger – An external I/O

Strona 7 - Introduction

22–2 Activation Mode Features ³ 9 1 9 6 0 0 ~ Variable Laser-On Time Out – Scan this bar code with a code byte sequence (on page 16–1) that repres

Strona 8 - Need To Start Over?

22–3 ³ 1 2 0 3 1 3 Detect and Notify Mode (Monitor the External Trigger) – The external I/O pin used in the default activation mode is monitored dur

Strona 10 - Code 39

23–1 Miscellaneous Features Custom Defaults Honeywell manufactures several scanners for OEM applications. These scanners may use a different set of

Strona 11 - ³ 1 0 7 7 0 5

23–2 Serial Program Mode For Serial Program Mode, all commands must be framed by an STX (02 Hex) and ETX (03 Hex). To recall defaults: 1. Transmit

Strona 12 - 2 OF 5 CODES

24–1 Customer Support Technical Assistance If you need assistance installing or troubleshooting your device, please call your distributor or the ne

Strona 13 - ³ 1 0 0 5 0 7

2–3 ³ 1 0 0 2 1 5 Enable PARAF (Italian Pharmaceutical Codes) Support – Code 39 bar codes are converted to PARAF format. ³ 1 0 0 2 0 5 * Disable

Strona 14 - Code 11

24–2 Product Service and Repair Honeywell International Inc. provides service for all its products through service centers throughout the world. To

Strona 15 - Plessey Codes

24–3 Online Product Service and Repair Assistance You can also access product service and repair assistance online at www.honeywellaidc.com

Strona 20 - ³ 1 0 1 2 0 5

Honeywell Scanning & Mobility 9680 Old Bailes Road Fort Mill, SC 29707 www.honeywellaidc.com 00-02544 Rev K 2/11

Strona 21 - ³ 1 0 1 0 0 1

2–4 ³ 1 1 5 4 1 3 Enable Alternate Code 39 Reference Comparison Check – assists with elements that are below the 2 to 1 (wide to narrow) element wid

Strona 22 - ³ 1 2 5 1 1 5

2–5 ³ 1 0 0 9 1 3 Alternative ITF first Bar Reference ³ 1 0 0 9 0 3 * Normal ITF first Bar Reference ³ 1 0 0 1 1 0 Enable Standard 2 of 5 ³ 1

Strona 23 - ³ 1 2 5 0 0 7

2–6 ³ 1 0 0 3 1 6 Enable Hong Kong 2 of 5 ³ 1 0 0 3 0 6 * Disable Hong Kong 2 of 5 ³ 1 1 5 4 1 1 Enable Follett ITF ³ 1 1 5 4 0 1 * Disable

Strona 24

2–7 ³ 1 0 0 0 0 3 * Disable Code 11 ³ 1 0 8 0 0 5 * Check for 1 Code 11 Check Digit ³ 1 0 8 0 1 5 Check for 2 Code 11 Check Digits ³ 1 0 8 0

Strona 25 - GS1 DataBar

2–8 ³ 2 0 0 7 3 4 Enable MSI Plessey MOD 10/10 Check Digit – Test MSI Plessey bar codes for a 2 digit Modulo 10 check digit. ³ 2 0 0 7 2 4 * Ena

Strona 26 - GS1 DataBar Expanded

2–9 ³ 9 0 1 8 0 0 ~ Minimum Symbol Length – Single-line default is 3. Combine this code with the proper code bytes (on page 16–1), to specify th

Strona 27 - ISBT Code 128 Implementation

2–10 ³ 9 0 2 2 0 0 ~ Code Length Lock #2 ³ 9 0 2 3 0 0 ~ Code Type Lock #2 ³ 9 0 2 4 0 0 ~ Code Length Lock #3 ³ 9 0 2 5 0 0 ~ Code Type L

Strona 28 - ³ 1 3 8 4 0 3

3–1 Supplements ³ 1 0 1 2 1 7 Enable Two Digit Supplements ³ 1 0 1 2 0 7 * Disable Two Digit Supplements ³ 1 0 1 2 1 2 * Enable Two Digit Redun

Strona 29 - ³ 9 3 8 3 0 0

Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this documen

Strona 30

3–2 ³ 1 0 1 4 1 7 Enable Bookland (978) Supplement Required ³ 1 0 1 4 0 7 * Disable Bookland (978) Supplement Required ³ 1 0 1 3 1 4 Enable 977

Strona 31 - Communications

3–3 ³ 1 0 1 0 0 0 * Enable 2 Digit Supplements with 37x, 43x, or UPC # System 5 ³ 1 0 1 0 1 0 Disable 2 Digit Supplements with 37x, 43x, or UPC #

Strona 32

3–4 ³ 1 0 1 2 1 4 Enable Code ID’s with Supplements ³ 1 0 1 2 0 4 * Disable Code ID’s with Supplements ³ 1 1 8 4 0 6 * Beep Once on Supplement

Strona 33 - Scanner Operation

3–5 ³ 1 0 1 2 1 0 Disable Supplemental when CodeGate Button is Pressed – Available for MS9540 scanners only. Requires standard Code Gate be inactive

Strona 35 - LED Options

4–1 GS1 DataBar Honeywell’s MS9520 Voyager® and MS9540 VoyagerCG® scanners with software #14810 and higher can be configured to scan GS1 DataBar typ

Strona 36 - Beeper Options

4–2 GS1 DataBar Limited ³ 1 0 0 4 1 4 Enable GS1 DataBar Limited ³ 1 0 0 4 0 4 * Disable GS1 DataBar Limited ³ 1 1 4 9 0 3 * Transmit GS1 Dat

Strona 37 - ³ 1 2 5 0 1 0

5–1 ISBT Code 128 Implementation Configuration Mode ³ 1 3 8 4 1 7 Enable ISBT Code 128 ³ 1 3 8 4 0 7 Disable ISBT Code 128 The bar codes below ena

Strona 38 - Data Transmission Delays

5–2 Concatenation Configuration Mode† The following bar codes are used to configure variable time requirements used to find the second bar code of t

Strona 39 - ³ 8 1 9 1 2 0 0

5–3 ³ 4 3 8 4 9 0 Donation Identification Number + Donor Identification Number =á + &; Concatenation ³ 4 3 8 4 1 0 0 Donation Identification

Strona 40 - Host Scanner Commands

iii Table of Contents Introduction Bar Code Configuration Methods ... 1–1 Single-Code Me

Strona 41 - ³ 1 1 8 2 1 3

5–4 The following example demonstrates how to configure the User-Defined ISBT identifiers: Assume the left-hand identifiers are the ISBT defined don

Strona 42 - Test Modes

6–1 Communications ³ 4 1 5 5 2 4 Enable Light Pen/Wand Communication – Use this option if scanner should be used in place of a light pen. ³ 4 1 5

Strona 44 - ³ 9 0 6 1 0 0

7–1 Scanner Operation Configuration Mode Options ³ 1 1 8 1 1 7 Allow Configuration Mode on Power Up – The scanner can only enter MetroSet mode bef

Strona 45 - ³ 1 2 4 7 1 6

7–2 Redundant Scans ³ 3 0 1 1 0 0 * 0 Redundant Scans – Requires 1 good decode for a good scan. ³ 3 0 1 1 1 0 1 Redundant Scan – Requires 2 cons

Strona 46 - Standard Prefix Characters

7–3 Same Symbol Time Outs The length of time before a bar code can be rescanned after it is removed from the scan field is user-configurable in incre

Strona 47 - ³ 1 1 6 1 1 1

7–4 Beeper Options ³ 3 1 8 5 7 5 * Normal Tone ³ 3 1 8 5 6 5 Optional Tone 1 ³ 3 1 8 5 5 5 Optional Tone 2 ³ 3 1 8 5 4 5 Optional Tone 3 ³

Strona 48 - Standard Suffix Characters

7–5 ³ 1 1 8 4 1 7 Beep on BEL Command – The scanner beeps when it receives a BEL character from the host. If a number is sent within 200 msecs befor

Strona 49 - Block Check Character

7–6 Data Transmission Delays Use these codes to select the amount of delay between sending data characters from the scanner to the host. This helps

Strona 50 - Character Replacements

7–7 Communication Time Out Options ³ 1 1 8 4 1 2 Enable Communications Time Out ³ 1 1 8 4 0 2 * Disable Communications Time Out ³ 1 1 8 4 1 3

Strona 51 - ³ 9 9 9 9 8 4

iv Scanner Operation Configuration Mode Options ... 7–1 Scan Buffers ...

Strona 52 - Special Formats

7–8 Host Scanner Commands ³ 1 1 8 0 1 5 Enable D/E Disable Command – The scanner will disable scanning after it receives an ASCII “D” from the host

Strona 53

7–9 ³ 1 1 5 9 1 6 Transmit Scanner ID byte with receipt of an “i” (69H) via RS232 – The ID byte is transmitted as 3 bytes (i.e. 0, 0, 1). ³ 1 1 5

Strona 54 - ³ 1 0 7 6 0 0

7–10 ³ 1 4 1 7 1 5 Use Protocol Prefix and Suffix for Bar Code Transmission ³ 1 4 1 7 0 5 * No Protocol Prefix and Suffix for Bar Code Transmissi

Strona 55 - Codabar Formatting

8–1 Prefixes/Suffixes Scan the Enter Configuration Mode bar code before trying to set these features (see the Multi-Code Method on page 1–1). User C

Strona 56 - Code 11 Formatting

8–2 User Configurable ID Characters, Code Specific ³ 1 0 5 5 0 7 * Use Configurable Code ID Bytes as Prefixes – User configured, code specific ID b

Strona 57 - 2 of 5 Code Formatting

8–3 ‡ Enter configuration mode then scan this bar code followed by the three code byte bar codes (on page 16–1) that represent a unique ID charact

Strona 58

8–4 Standard Prefix Characters ³ 1 1 6 6 1 5 Enable STX Prefix – The scanner will transmit a Start of TeXt (ASCII 02H) before each bar code. ³ 1

Strona 59 - Baud Rate

8–5 ³ 1 0 7 9 1 6 Enable SANYO ID Characters ³ 1 0 7 9 0 6 * Disable SANYO ID Characters ³ 1 0 5 5 1 2 Enable Manufacturer ID Prefix ³ 1 0 5

Strona 60 - Hardware Handshaking

8–6 ³ 1 2 4 6 1 0 Enable Tec 7-11 IDs ³ 1 2 4 6 0 0 * Disable Tec 7-11 IDs Standard Suffix Characters ³ 1 1 6 6 1 3 * Enable CR Suffix – The sc

Strona 61 - ³ 1 1 5 8 0 7

8–7 ³ 9 4 1 6 0 0 Enable NCR Suffix Character Longitudinal Redundancy Check A Longitudinal Redundancy Check (LRC) is an error checking character t

Strona 62 - Software Handshaking

v RS232 Parity Features ... 10–1 Baud Rate ...

Strona 63 - Miscellaneous

8–8 Character Replacements To replace a character: 1. Scan the enter/exit configuration mode bar code (on page 1–1). 2. Scan the character to repl

Strona 64

8–9 User Configurable Suffixes, All Data Note: Scan the Enter/Exit Configuration mode code before trying to set this feature. Refer to Multi-Code M

Strona 65 - Keyboard

8–10 Special Formats ³ 1 0 7 9 1 4 Enable SINEKO Mode ³ 1 0 7 9 0 4 * Disable SINEKO Mode ³ 1 1 6 7 1 1 Enable Newcode Formatting Mode A ³ 1

Strona 66 - Keyboard/System Type

9–1 Code Formatting UPC/EAN Formatting ³ 1 0 7 5 1 7 * Transmit UPC-A Check Digit ³ 1 0 7 5 0 7 Do Not Transmit UPC-A Check Digit ³ 1 0 7 5 1 6

Strona 67 - ‘Dumb’ Terminal Selections

9–2 ³ 1 0 7 5 1 3 Transmit Lead Zero on UPC-E – This option will transmit a zero before each UPC-E bar code. ³ 1 0 7 5 0 3 Do Not Transmit Lead Ze

Strona 68 - Special Keyboard Features

9–3 Codabar Formatting ³ 1 0 7 7 1 7 Transmit Codabar Start/Stop Characters –Transmits Codabar’s Start/stop characters before and after each bar co

Strona 69 - ³ 1 1 6 3 0 4

9–4 Code 39 Formatting ³ 1 0 7 7 1 5 Transmit Mod 43 Check Digit on Code 39 – This feature works in conjunction with Mod 43 Check Digit on Code 39 o

Strona 70 - InterScan Code Delays

9–5 Plessey ³ 1 0 7 8 1 6 Transmit UK Plessey Check Digit – The scanner will transmit UK Plessey Check Digit characters and must be used with the U

Strona 72

10–1 RS232 ³ 4 1 5 5 5 4 * Enable RS232 Mode – The scanner will work with RS232 +/-12V serial output. Parity Features A parity bit is an extra dat

Strona 73 - ³ 9 9 9 9 9 3

vi MS9520 Voyager® and MS9540 VoyagerCG® Series Activation Range ...

Strona 74

10–2 ³ 4 1 5 8 5 0 * 9600 BAUD Rate ³ 4 1 5 8 4 0 4800 BAUD Rate ³ 4 1 5 8 3 0 2400 BAUD Rate ³ 4 1 5 8 2 0 1200 BAUD Rate ³ 4 1 5 8 1 0 60

Strona 75 - Light Pen Parameters

10–3 ³ 1 1 5 8 1 5 * Character RTS/CTS – Activates/Deactivates RTS signal for each character. ³ 1 1 5 8 0 5 Message RTS/CTS – Activates RTS befor

Strona 76 - Set Narrow Element Width

10–4 ³ 1 1 5 9 1 5 Enable RTS Counter Toggle – The scanner will toggle the RTS line on a good decode. ³ 1 1 5 9 0 5 * Disable RTS Counter Toggle

Strona 77 - 46xx Configuration

10–5 ³ 1 1 5 8 1 4 Enable 5 NAK Retries Allow up to 5 retransmissions of the data if a NAK is received. ³ 1 1 5 8 0 4 * Disable 5 NAK Retries

Strona 79 - ³ 9 9 9 9 7 8

11–1 Keyboard Enable Keyboard Emulation ³ 9 9 9 9 9 4 Load Keyboard Wedge Defaults – Loads the default settings for keyboard wedge mode. ³ 5 1 5

Strona 80 - ³ 9 9 9 9 7 2

11–2 ³ 4 1 6 2 0 0 Belgium Keyboard ³ 4 1 6 2 1 0 0 Japan Keyboard ³ 4 1 6 2 7 0 IBM 4700 Financial Keyboard ³ 4 1 6 2 9 0 Sweden/Finland Keyb

Strona 81 - Code Bytes Usage

11–3 ‘Dumb’ Terminal Selections Note: The following terminals may require custom cables. ³ 3 1 6 4 0 0 IBM Terminal Keyboards ³ 3 1 6 4 1 0 Reser

Strona 82 - Code Type Table

11–4 Special Keyboard Features ³ 1 1 6 3 1 1 Transmit Make Code Only – Not available on all models. ³ 1 1 6 3 0 1 * Transmit Make/Break Code – N

Strona 83 - ASCII Reference Table

11–5 ³ 1 1 6 2 1 4 Enable Auto Detect Mode (AT/PS2) – Automatically detects caps lock status. ³ 1 1 6 2 0 4 * Disable Auto Detect Mode (AT/PS2)

Strona 84

1–1 Introduction Your new scanner has been factory configured with a set of default parameters. Since many host systems have unique formats and prot

Strona 85

11–6 ³ 1 1 6 3 0 2 Enable Right Alt Key Sequencing ³ 1 1 6 3 1 2 Disable Right Alt Key Sequencing ³ 1 1 6 4 1 3 Enable LaCaixa Special Keyboard

Strona 86

11–7 Control Sets In general, standard bar code symbologies will only encode the ASCII character set. Function keys, arrow keys and many other exte

Strona 87

11–8 ASCII (HEX) ASCII Control Extended Key 00H Null Numeric Keypad + (Plus) 01H SOH Num Lock 02H STX Down Arrow 03H ETX Numeric Keypad -

Strona 88

12–1 OCIA ³ 4 1 5 5 4 4 Enable OCIA Mode – Select this option if communications requires OCIA (Optically Coupled Interface Adapter). The host clock

Strona 90 - Laser/Scan Modes

13–1 Light Pen Parameters ³ 4 1 5 5 2 4 Enable Light Pen Mode – Select this option if the scanner will be used in place of a light pen. It provides

Strona 91

13–2 Set Narrow Element Width ³ 1 1 6 9 1 2 10x Narrow Element Border – Allows the transmission of Light Pen/Wand emulation using a 10x border. ³

Strona 92 - ³ 1 1 7 0 1 1

14–1 IBM® 46xx Configuration IBM Port ³ 4 1 5 5 0 4 Enable RS485 Communication – For RS485 communications. Not all scanners support this interface.

Strona 94 - ³ 1 1 5 0 1 3

15–1 USB ³ 4 1 5 5 1 1 4 Enable USB Interface♦ ³ 9 9 9 9 7 8 Enable Low Speed USB Defaults♦ ♦ This feature is limited to Honeywell scanners w

Strona 95 - MS9535 VoyagerBT

1–2 Need To Start Over? Scan the Recall Defaults bar code to erase all previous settings and return the scanner to its factory default communicatio

Strona 96 - ³ 1 2 3 7 1 2

15–2 ³ 3 1 6 4 7 0 Enable Uni-Directional USB Serial Emulation Mode –Supported in Honeywell MS9500, MS5100 and IS4125 laser-class products. Note:

Strona 97 - MS9535-5M VoyagerBT

16–1 Code Bytes Usage The scanner must be in Configuration Mode for the features requiring code bytes for configuration. The Enter/Exit Configuratio

Strona 98 - ³ 1 2 3 9 1 5

16–2 ³ 8 Code Byte 8 ³ 9 Code Byte 9 Reserved Codes ³ 9 9 9 9 8 8 ~ Enable Reserved Code – Contact Honeywell for information about this feature

Strona 99

16–3 ASCII Reference Table HEX Value Decimal Value/ Code Byte Value Character Control Keyboard Eqv 00 000 NUL @ 01 001 SOH A 02 002 STX B

Strona 100

16–4 HEX Value Decimal Value/ Code Byte Value Character Control Keyboard Eqv 1D 029 GS ^ 1E 030 RS _ 1F 031 US space,blank 20 032 SP 21

Strona 101 - ³ 8 4 6 6 0 1 1 0

16–5 HEX Value Decimal Value/ Code Byte Value Character Control Keyboard Eqv 3C 060 < less than 3D 061 = 3E 062 > greater than 3F 0

Strona 102

16–6 HEX Value Decimal Value/ Code Byte Value Character Control Keyboard Eqv 5A 090 Z 5B 091 [ shift K 5C 092 \ shift L 5D 093 ] shift

Strona 103 - Operating Modes

16–7 HEX Value Decimal Value/ Code Byte Value Character Control Keyboard Eqv 79 121 y 7A 122 z 7B 123 { 7C 124 | vertical slash 7D 1

Strona 104 - Activation Mode Features

16–8 Key At Scan Code PS2 Scan Code 3151 Prefix/Suffix Value Hex = Decimal F8 0AH 42H 3FH 97H = 151 F9 01H 43H 47H 98H = 152 F10 09H 44H

Strona 105 - Sleep Mode

17–1 MS9520 Voyager® and MS9540 VoyagerCG® Series Activation Range Use these bar codes to select infrared (IR) sensor activation range for sensing w

Strona 106

2–1 Code Types and Decode Rules Bar code descriptions marked with an asterisk ( * ) define a feature that is a factory default. Bar codes marked with

Strona 107 - Miscellaneous Features

17–2 ³ 1 1 8 7 1 3 * CodeGate Active Out of Stand ³ 1 1 8 7 0 3 CodeGate Inactive Out of Stand Laser/Scan Modes ³ 4 1 8 3 0 4 * Normal Scan –

Strona 108 - Serial Program Mode

17–3 Same Symbol Time Outs If using an MS5145 Eclipse, the MS9524 or MS9544 VoyagerPDF, go to page 7–3. ³ 8 1 8 9 0 0 No Same Symbol Time Out ³ 8

Strona 109 - Customer Support

17–4 MS9520-00 and MS9540-00 Laser Emulation Mode The MS9520-00 and MS9540-00 leave the factory with Laser Emulation interface enabled. If you recall

Strona 110 - Product Service and Repair

18–1 MS9524 and MS9544 VoyagerPDF® Series ³ 1 0 0 0 1 0 * Enable PDF ³ 1 0 0 0 0 0 Disable PDF ³ 1 1 5 0 1 0 * Enable Audible Indicator ³ 1

Strona 111

18–2 ³ 1 1 5 0 1 7 Disable GS1 DataBar 2D Linkage ³ 1 1 5 0 1 6 Enable UPC/EAN Linkage – Link UPC/EAN symbols with a 2D composite constituent then

Strona 112

19–1 MS9535 VoyagerBT® The MS9535 can act as a client to other devices equipped with Bluetooth® wireless technology. If the device’s address is a 12-

Strona 113

19–2 ³ 8 1 9 5 1 2 0 Sleep in 2 Minutes – The scanner will go into sleep mode after the laser has been off for 2 minutes. ³ 8 1 9 5 3 0 0 Sleep i

Strona 114

20–1 MS9535-5M VoyagerBT ³ 1 2 3 9 1 0 Enable Inventory Mode – Bar code data that is scanned is stored in the scanner’s expanded memory base. The da

Strona 115

20–2 ³ 9 9 8 0 4 9 Clear Inventory Records – Will clear all stored bar code data in memory. ³ 1 2 5 6 1 2 Enable Auto Clear Records – Will automat

Strona 116

20–3 Inventory Quantity Bar Codes** The following inventory quantity bar codes will enable the user to enter a quantity from 1 to 9999 for the last i

Komentarze do niniejszej Instrukcji

Brak uwag