Honeywell K14114 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Systemy kontroli dostępu bezpieczeństwa Honeywell K14114. Honeywell K14114 User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Security Systems

ADEMCO LYNXR-I Security Systems Installation and Setup Guide AWAYOFFSTAYAUX4567890#123 K14114 3/06 Rev. B

Strona 2 - 01000-002-V0

LYNXR-I Installation and Setup Guide - 10 - LRR/IP Communications Device 24-Hour Standby Power If you are installing the AlarmNet 7845GSM/7845i-GSM o

Strona 3 - Table of Contents

LYNXR-I Installation and Setup Guide - 11 - AC Power and Backup Battery The system is powered by a 9VAC, 25VA Plug-in Transformer, ADEMCO K10145X10

Strona 4 - System Features

LYNXR-I Installation and Setup Guide - 12 - AC Power and Rechargeable Backup Battery The LYNXR-I is equipped with an integral, replaceable, rechargea

Strona 5 - (1 of 3)

LYNXR-I Installation and Setup Guide - 13 - Installing Wireless Zones General Information Zones: The control supports up to 24 wireless zones using 5

Strona 6 - Wiring Connections

LYNXR-I Installation and Setup Guide - 14 - Transmitter Battery Life • Batteries in the wireless transmitters may last from 4–7 years, depending o

Strona 7

LYNXR-I Installation and Setup Guide - 15 - 5800 Series Transmitter Loop Numbers (Refer to this information when programming transmitters) The followi

Strona 8 - General

LYNXR-I Installation and Setup Guide - 16 - Mechanics of Programming General Programming Information Programming options are stored in non-removable

Strona 9 - LYNXR-I CONTROL PANEL

LYNXR-I Installation and Setup Guide - 17 - Interactive Menu Mode Programming (✻56, ✻80, ✻81, ✻83, ✻84, ✻85) Press [✻] + interactive mode No. (i.e., ✻

Strona 10 - Connecting AlarmNet 7845CV2

LYNXR-I Installation and Setup Guide - 18 - Zone Response Type Definitions General Information During programming, you must assign a zone type to eac

Strona 11 - AC Power and Backup Battery

LYNXR-I Installation and Setup Guide - 19 - Zone Response Type Definitions Type 07 24-hour Audible Alarm Zone type 07 is usually assigned to a zone

Strona 12 - LYNXRCHKIT-SHA

- 2 - RECOMMENDATIONS FOR PROPER PROTECTION The Following Recommendations for the Location of Fire and Burglary Detection Devices Help Provide Prope

Strona 13 - Installing Wireless Zones

LYNXR-I Installation and Setup Guide - 20 - Data Field Descriptions Defaults (where applicable) are Indicated in bold text. The following pages list

Strona 14

LYNXR-I Installation and Setup Guide - 21 - Data Field Descriptions ✻34 Exit Delay 00-99 = exit delay time in seconds The system will wait the time en

Strona 15 - 5800RL DIP SWITCH TABLE

LYNXR-I Installation and Setup Guide - 22 - Data Field Descriptions All four digits of the Subscriber Account number must be entered in Fields ✻43 a

Strona 16 - Mechanics of Programming

LYNXR-I Installation and Setup Guide - 23 - Data Field Descriptions ✻49 Split/Dual Reporting To Primary To Secondary 0 = All reports None, unless

Strona 17 - Loading Factory Defaults

LYNXR-I Installation and Setup Guide - 24 - Data Field Descriptions ✻58 RF Jam Detection 0 = no jam detection 1 = RF jam detection with event loggin

Strona 18 - General Information

LYNXR-I Installation and Setup Guide - 25 - Data Field Descriptions ✻63 Low Battery Report Code (See notes above) This will be sent when a low batter

Strona 19 - 01000-020-V0

LYNXR-I Installation and Setup Guide - 26 - Data Field Descriptions To ensure that the LYNXR-I properly transmits its reports to the Central Station

Strona 20 - Data Field Descriptions

LYNXR-I Installation and Setup Guide - 27 - Data Field Descriptions ✻87 AUX Function/1-Button Paging 0 = Aux key performs defined function (macro) 1 =

Strona 21

LYNXR-I Installation and Setup Guide - 28 - Data Field Descriptions DOWNLOAD INFORMATION (✻94, ✻95) ✻94 Download Call Back Phone Number Enter up to

Strona 22

LYNXR-I Installation and Setup Guide - 29 - ✻56 Enhanced Zone Programming Mode This is an interactive menu mode that is used to program zone numbers

Strona 23

- 3 - Table of Contents SYSTEM FEATURES ...

Strona 24

LYNXR-I Installation and Setup Guide - 30 - ✻56 Enhanced Zone Programming Mode While in Program mode, press ✻56 to enter Zone Programming Menu Mode.

Strona 25

LYNXR-I Installation and Setup Guide - 31 - ✻56 Enhanced Zone Programming Mode E l Loop number or Loop and Serial number (if using RF Learn

Strona 26

LYNXR-I Installation and Setup Guide - 32 - ✻56 Enhanced Zone Programming Mode IA LC Enroll mode 0 = advance to the VOICE DESCRIPTOR prompt (1C).

Strona 27

LYNXR-I Installation and Setup Guide - 33 - ✻56 Enhanced Zone Programming Mode Id vi Descriptor 1 Enter [#] + 2-digit vocabulary index number† of

Strona 28

LYNXR-I Installation and Setup Guide - 34 - ✻80 Device Programming Menu Mode Powerline Carrier devices (eg., X10 brand devices) are programmable swi

Strona 29

LYNXR-I Installation and Setup Guide - 35 - ✻80 Device Programming Menu Mode STOP The "STOP" programming determines when and under what co

Strona 30 - b zt

LYNXR-I Installation and Setup Guide - 36 - ✻80 Device Programming Menu Mode The following explains these prompts in detail. The left two columns ide

Strona 31 - E l

LYNXR-I Installation and Setup Guide - 37 - ✻81 Zone List Menu Mode While in Program mode, press ✻81 to enter Zone List Menu Mode. This mode is used

Strona 32 - IA LC

LYNXR-I Installation and Setup Guide - 38 - ✻83 Enhanced Sequential Mode By using this mode, you can add, delete, or change the serial number of a t

Strona 33 - IF vi

LYNXR-I Installation and Setup Guide - 39 - ✻83 Enhanced Sequential Mode IA zz IA LC Enroll mode 0 = advance to next zone to be enrolle

Strona 34 - Programming Options Defined

LYNXR-I Installation and Setup Guide - 4 - System Features UUUULLLL LYNXR-I is not intended for UL985 Household Fire applications unless a 24-hou

Strona 35

LYNXR-I Installation and Setup Guide - 40 - ✻83 Enhanced Sequential Mode Ib zz Ib Serial number Enter transmitter’s 7- digit serial number via

Strona 36

LYNXR-I Installation and Setup Guide - 41 - ✻84 Assign Zone Voice Descriptors Use this mode to assign voice descriptors for each zone. These are the

Strona 37 - 81 Zone List Menu Mode

LYNXR-I Installation and Setup Guide - 42 - ✻84 Assign Zone Voice Descriptor VOICE VOCABULARY INDEX 00 ½ second pause A 82 ALARM 32 ATTIC B 01

Strona 38 - 83 Enhanced Sequential Mode

LYNXR-I Installation and Setup Guide - 43 - ✻85 Record Custom Voice Descriptors Use this mode to record up to 5 custom voice descriptors. Press ✻85

Strona 39

LYNXR-I Installation and Setup Guide - 44 - Voice Prompt Programming The LYNXR-I features a quick programming mode that allows you to program the sy

Strona 40

LYNXR-I Installation and Setup Guide - 45 - Voice Prompt Programming Enter Voice Prompt Programming Mode: (Installer Code + 8 8 8). Follow the voice

Strona 41

LYNXR-I Installation and Setup Guide - 46 - Voice Prompt Programming To Delete Sensors To Add an Emergency Pendant (5) Pendant Type Medical Fire

Strona 42 - VOICE VOCABULARY INDEX

LYNXR-I Installation and Setup Guide - 47 - Voice Prompt Programming All four digits of the Central Station Account number must be entered. If ten-

Strona 43 - Custom descriptor number

LYNXR-I Installation and Setup Guide - 48 - Remote Programming/Control (Downloading) General Information The control panel can be remotely programmed

Strona 44 - Voice Prompt Programming

LYNXR-I Installation and Setup Guide - 49 - Remote Programming/Control (Downloading) • Command the system to upload a copy of its resident program t

Strona 45

LYNXR-I Installation and Setup Guide - 5 - Mounting the Control Wall Mounting The illustration below shows the front assembly separated from the bac

Strona 46

LYNXR-I Installation and Setup Guide - 50 - System Operation Security Codes Installer Code The installer programs the 4-digit Installer Code initiall

Strona 47

LYNXR-I Installation and Setup Guide - 51 - System Operation Keypad Functions The keypad allows the user to arm and disarm the system, and perform

Strona 48

LYNXR-I Installation and Setup Guide - 52 - System Operation To use the defined AUX function: Press and hold AUX key 2 secs (4 beeps) +

Strona 49

LYNXR-I Installation and Setup Guide - 53 - System Operation UUUULLLL Audio alarm verification has not been evaluated by UL. Audio Alarm Verif

Strona 50 - System Operation

LYNXR-I Installation and Setup Guide - 54 - System Operation “Follow Me” Reminder Feature This feature allows the user to schedule a time driven mes

Strona 51

LYNXR-I Installation and Setup Guide - 55 - System Operation System Displays Display Meaning PC Remote Phone Control feature is active (Appears in

Strona 52

LYNXR-I Installation and Setup Guide - 56 - Testing the System Test ModeAfter installation is completed, the security system should be carefully tes

Strona 53

LYNXR-I Installation and Setup Guide - 57 - System Communication This section provides an explanation of formats this system accommodates for rep

Strona 54

LYNXR-I Installation and Setup Guide - 58 - System Communication Report 3+1/4+1 Standard 3+1/4+1 Expanded 4+2 Alarm SSS(S) A SSS(S) A AAA(A)

Strona 55

LYNXR-I Installation and Setup Guide - 59 - Troubleshooting Guide Trouble Conditions The word “FAULT” on the keypad’s display, accompanied by a ra

Strona 56 - Testing the System

LYNXR-I Installation and Setup Guide - 6 - Wiring Connections Wiring Overview The following summarizes the connections required. Refer to the Wiring

Strona 57 - System Communication

LYNXR-I Installation and Setup Guide - 60 - Troubleshooting Guide System (including Wireless) SYMPTOM POSSIBLE CAUSE REMEDY 1. Transmitter signal

Strona 58

LYNXR-i Installation and Setup Guide - 61 - Troubleshooting Guide Control SYMPTOM POSSIBLE CAUSE REMEDY 1. The word “AC” is not displayed. 1a.

Strona 59 - Troubleshooting Guide

LYNXR-I Installation and Setup Guide - 62 - Programming Default Tables (boldface indicates defaults that differ between tables) Function Table 1 T

Strona 60

LYNXR-I Installation and Setup Guide - 63 - Programming Default Tables (boldface indicates defaults that differ between tables) Function Table 1

Strona 61

LYNXR-I Installation and Setup Guide - 64 - Programming Default Tables ✻56 ZONE ASSIGNMENT/ALARM REPORT CODES FOR TABLES 3 & 4 Zone No. Zone Typ

Strona 62 - Programming Default Tables

LYNXR-I Installation and Setup Guide - 65 - – Index – *56 Enhanced Zone Programming Mode... 13, 24, 28, 29 *80 Device Programming...

Strona 63

LYNXR-I Installation and Setup Guide - 66 - Exit Delay ... 21, 59, 62 Exit Delay Res

Strona 64

LYNXR-I Installation and Setup Guide - 67 - RF... 30 RF

Strona 65 - – Index –

LYNXR-I Installation and Setup Guide - 68 - Regulatory Agency Statements UL NOTICE: This is a "Grade A" residential system FCC STATEMENT

Strona 66

LYNXR-I Installation and Setup Guide - 69 - WARNING THE LIMITATIONS OF THIS ALARM SYSTEM While this System is an advanced design security syste

Strona 67 - - 67

LYNXR-I Installation and Setup Guide - 7 - Wiring Connections 1. Make Earth Ground Connection - The designated earth ground terminal (1) must be ter

Strona 68 - Regulatory Agency Statements

LYNXR-I Installation and Setup Guide - 70 - Specifications LYNXR-I Security Controls 1. Physical: 10-3/8” W x 7-1/8” H x 1-3/4” D 2. Electrical

Strona 69

- 71 - INCOMINGPHONELINETO HANDSETPHONELINEWEEKLY TESTING ISREQUIRED TO ENSUREPROPER OPERATIONOF THIS SYSTEMALL OUTPUT CIRCUITS ARE POWER LIMITED.

Strona 70 - Specifications

LIMITED WARRANTY Honeywell International Inc. acting through its Security & Custom Electronics business ("Seller"), 165 Eileen Way, S

Strona 71 - - 71

LYNXR-I Installation and Setup Guide - 8 - Connecting/Configuring Communication Modules General This LYNXR-I supports central station reporting via l

Strona 72 - ‡K14114ÉŠ

LYNXR-I Installation and Setup Guide - 9 - AlarmNet 7845GSM*, 7845i-GSM*, 7845i-ENT or 7845i, Communications Device The 7845i-ENT/7845i and 7845CV2 c

Komentarze do niniejszej Instrukcji

Brak uwag